:source: fmgd_system_icond.py
:orphan:
.. _fmgd_system_icond:
fmgd_system_icond -- Configure Industrial Connectivity.
+++++++++++++++++++++++++++++++++++++++++++++++++++++++
.. versionadded:: 1.0.0
.. contents::
:local:
:depth: 1
Synopsis
--------
- This module is able to configure a FortiManager device.
- Examples include all parameters and values need to be adjusted to data sources before usage.
- Tested with FortiManager v7.x.
Requirements
------------
The below requirements are needed on the host that executes this module.
- ansible-core>=2.16.0
FortiManager Version Compatibility
----------------------------------
.. raw:: html
Supported Version Ranges: v7.4.3 -> latest
Parameters
----------
.. raw:: html
- access_token -The token to access FortiManager without using username and password. type: str required: false
- bypass_validation - Only set to True when module schema diffs with FortiManager API structure, module continues to execute without validating parameters. type: bool required: false default: False
- enable_log - Enable/Disable logging for task. type: bool required: false default: False
- forticloud_access_token - Access token of forticloud managed API users, this option is available with FortiManager later than 6.4.0. type: str required: false
- proposed_method - The overridden method for the underlying Json RPC request. type: str required: false choices: set, update, add
- rc_succeeded - The rc codes list with which the conditions to succeed will be overriden. type: list required: false
- rc_failed - The rc codes list with which the conditions to fail will be overriden. type: list required: false
- workspace_locking_adom - Acquire the workspace lock if FortiManager is running in workspace mode. type: str required: false choices: global, custom adom including root
- workspace_locking_timeout - The maximum time in seconds to wait for other users to release workspace lock. type: integer required: false default: 300
- device - The parameter in requested url type: str required: true
- system_icond - Configure Industrial Connectivity. type: dict
- iec101_keepalive (Alias name: iec101-keepalive) Send periodic test frame for probing link status. type: str choices: [disable, enable]
more...
Supported Version Ranges: v7.4.3 -> latest
- iec101_laddr_local (Alias name: iec101-laddr-local) Link address of local. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec101_laddr_remote (Alias name: iec101-laddr-remote) Link address of remote. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec101_laddr_size (Alias name: iec101-laddr-size) Link address size. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec101_mode (Alias name: iec101-mode) Link layer transmission procedure. type: str choices: [balanced, unbalanced]
more...
Supported Version Ranges: v7.4.3 -> latest
- iec101_t0 (Alias name: iec101-t0) Time out for repetition of frames in milliseconds (1 - 30000, default = 500). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec101_trp (Alias name: iec101-trp) Time interval during which repetitions are permitted in milliseconds (1 - 300000, default = 2500). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec101_use_ack_char (Alias name: iec101-use-ack-char) Use single character for ack. type: str choices: [disable, enable]
more...
Supported Version Ranges: v7.4.3 -> latest
- iec104_k (Alias name: iec104-k) Maximum number of outstanding i formate apdus (1 - 32767, default = 12). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec104_t1 (Alias name: iec104-t1) Time-out of send or test apdus in seconds (1 - 255, default = 15). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec104_t2 (Alias name: iec104-t2) Time-out for acknowledges in case no data messages in seconds (1 - 255, default = 10). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec104_t3 (Alias name: iec104-t3) Time-out for sending test frames in case of a long idle state in seconds (1 - 172800, default = 20). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- iec104_w (Alias name: iec104-w) Maximum number of latest acknowledge apdus (1 - 32767, default = 8). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- modbus_serial_addr (Alias name: modbus-serial-addr) Serial remote station address. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- modbus_serial_mode (Alias name: modbus-serial-mode) Serial transmission mode. type: str choices: [RTU, ASCII]
more...
Supported Version Ranges: v7.4.3 -> latest
- modbus_serial_timeout_resp (Alias name: modbus-serial-timeout-resp) Time out for serial remote station response in milliseconds (10 - 30000, default = 500). type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- modbus_tcp_unit_id (Alias name: modbus-tcp-unit-id) Tcp mbap unit identifier. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- port Listening socket port. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- status Enable/disable this connection. type: str choices: [disable, enable]
more...
Supported Version Ranges: v7.4.3 -> latest
- tty_baudrate (Alias name: tty-baudrate) Tty baudrate. type: str choices: [200, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 115200]
more...
Supported Version Ranges: v7.4.3 -> latest
- tty_databits (Alias name: tty-databits) Tty databits. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- tty_device (Alias name: tty-device) Tty device. type: str
more...
Supported Version Ranges: v7.4.3 -> latest
- tty_flowcontrol (Alias name: tty-flowcontrol) Tty flowcontrol. type: str choices: [none, xon-xoff, hw]
more...
Supported Version Ranges: v7.4.3 -> latest
- tty_parity (Alias name: tty-parity) Tty parity. type: str choices: [none, odd, even]
more...
Supported Version Ranges: v7.4.3 -> latest
- tty_stopbits (Alias name: tty-stopbits) Tty stopbits. type: int
more...
Supported Version Ranges: v7.4.3 -> latest
- type Connection type. type: str choices: [iec101-104, modbus-serial-tcp, raw]
more...
Supported Version Ranges: v7.4.3 -> latest
Notes
-----
.. note::
- Running in workspace locking mode is supported in this FortiManager module, the top level parameters workspace_locking_adom and workspace_locking_timeout help do the work.
- To create or update an object, use state: present directive.
- To delete an object, use state: absent directive
- Normally, running one module can fail when a non-zero rc is returned. you can also override the conditions to fail or succeed with parameters rc_failed and rc_succeeded
Examples
--------
.. code-block:: yaml+jinja
- name: Example playbook (generated based on argument schema)
hosts: fortimanagers
connection: httpapi
gather_facts: false
vars:
ansible_httpapi_use_ssl: true
ansible_httpapi_validate_certs: false
ansible_httpapi_port: 443
tasks:
- name: Configure Industrial Connectivity.
fortinet.fmgdevice.fmgd_system_icond:
# bypass_validation: false
# workspace_locking_adom:
# workspace_locking_timeout: 300
# rc_succeeded: [0, -2, -3, ...]
# rc_failed: [-2, -3, ...]
device:
system_icond:
# iec101_keepalive:
# iec101_laddr_local:
# iec101_laddr_remote:
# iec101_laddr_size:
# iec101_mode:
# iec101_t0:
# iec101_trp:
# iec101_use_ack_char:
# iec104_k:
# iec104_t1:
# iec104_t2:
# iec104_t3:
# iec104_w:
# modbus_serial_addr:
# modbus_serial_mode:
# modbus_serial_timeout_resp:
# modbus_tcp_unit_id:
# port:
# status:
# tty_baudrate:
# tty_databits:
# tty_device:
# tty_flowcontrol:
# tty_parity:
# tty_stopbits:
# type:
Return Values
-------------
Common return values are documented: https://docs.ansible.com/ansible/latest/reference_appendices/common_return_values.html#common-return-values, the following are the fields unique to this module:
.. raw:: html
- meta - The result of the request.returned: always type: dict
- request_url - The full url requested. returned: always type: str sample: /sys/login/user
- response_code - The status of api request. returned: always type: int sample: 0
- response_data - The data body of the api response. returned: optional type: list or dict
- response_message - The descriptive message of the api response. returned: always type: str sample: OK
- system_information - The information of the target system. returned: always type: dict
- rc - The status the request. returned: always type: int sample: 0
- version_check_warning - Warning if the parameters used in the playbook are not supported by the current FortiManager version. returned: if at least one parameter not supported by the current FortiManager version type: list
Status
------
- This module is not guaranteed to have a backwards compatible interface.
Authors
-------
- Xinwei Du (@dux-fortinet)
- Xing Li (@lix-fortinet)
- Jie Xue (@JieX19)
- Link Zheng (@chillancezen)
- Frank Shen (@fshen01)
- Hongbin Lu (@fgtdev-hblu)